Warranty: | One Year |
---|---|
Display Type: | Digital Only |
Certification: | CE |
Customized: | Customized |
Transport Package: | Box |
Trademark: | Neutral/KASUNTEST |
Customization: |
---|
Suppliers with verified business licenses
Function
|
Two three four-wire measure grounding resistance, soil resistivity;
Ground voltage, AC voltage measurement |
Ambient temperature and humidity
|
23ºC±5ºC,below 75%rh
|
Power
|
8.4V lithium battery (built-in)
|
Interference voltage
|
<20V (should be avoided)
|
Interference current
|
<2A (should be avoided)
|
Measure R electrode spacing
|
a>5d
|
Measured electrode spacing
|
a>20h
|
Auxiliary ground resistance
|
Reference condition <100Ω, working condition <5kΩ
|
Range
|
Grounding resistance: 0.00Ω~30.00kΩ
|
Soil resistivity: 0.00Ωm~9999kΩm
|
|
Grounding voltage: 0.00V~100.0V
|
|
measurement mode
|
Precise four-wire, three-wire measurement, simple two-wire measurement
|
Measurement methods
|
Grounding resistance: rated current change pole method
Soil resistivity: four-pole method Ground Voltage: Average Rectification(between S-ES interface) |
Test frequency
|
128Hz
|
Short circuit test current
|
> 20mA (Sine Wave)
|
Open circuit test voltage
|
AC 28V max
|
Electrode spacing range
|
Can be set 1m ~ 100m
|
Change gear
|
fully automatic shifting 0.00Ω ~ 30.00kΩ
|
fully automatic shifting 0.00Ωm~9000kΩm
|
|
Backlight
|
Controllable gray screen backlight, suitable for use in dim places
|
Display mode
|
4-bit large LCD display, gray screen backlight
|
Measurement instructions
|
LED flashing indicator during measurement
|
LCD size
|
111mm×68mm
|
LCD display field
|
108mm×65mm
|
Instrument size
|
L/W/H:277.2mm×227.5mm×153mm
|
Standard test line length
|
4 strips:red 15m,black 15m, yellow 10m,green 10m each one
|
Simple test line
|
2strips:yellow 1.6m,green 1.6m each one
|
Auxiliary Grounding rod
|
4PCS:φ10mm×200mm
|
Measure time
|
Ground voltage:about 3 times/sec;
|
grounding resistance,soil resistivity: about 7 seconds/time
|
|
Line voltage
|
Measurement below AC100V (ground voltage measurement function cannot be used to measure commercial power)
|
USB interface
|
With USB interface, software monitoring, storage data can be uploaded to the computer, save and print
|
Communication Line
|
One USB communication line, 1.5m long
|
Data storage
|
500 groups, "MEM" storage indicates, flashing "FULL" symbol indicates that the memory is full
|
Data review
|
Data review function: "MR" symbol display
|
Overflow display
|
Over-range overflow function: "OL" symbol display
|
Interference test
|
Automatic identification of interference signals, "NOISE" symbol indication when the interference voltage is higher than 5V
|
Auxiliary grounding test
|
With auxiliary ground resistance test function, 0.00KΩ ~ 30kΩ (Rh max = 3kΩ +100R <50kΩ; Rs max = 3kΩ +100R <50kΩ)
|
Alarm function
|
Alarm when the measured value exceeds the alarm setting value
|
Battery voltage
|
Real-time display of battery power, reminding timely charging when battery voltage is low
|
Automatic Shutdown
|
"APO" Indicates, automatic Shutdown After 15 Minutes
|
Power consumption
|
Standby: 40mA Max(Backlight off)
|
Turn on backlight: about 43mA
|
|
measuring:75mA Max(Backlight off)
|
|
Weight
|
Instrument: 2450g(including battery)
|
Test lines:1300g
|
|
Auxiliary grounding rod: 850g(4PCS)
|
|
Working temperature and humidity
|
-10ºC~40ºC;below 80%rh
|
Storage temperature and humidity
|
-20ºC~60ºC;below 70%rh
|
Overload protection
|
Grounding resistance:AC 280V/3 seconds between H-E and S-ES ports
|
Insulation resistance
|
20MΩ(500V between circuit and housing)
|
Pressure resistance
|
AC 3700V/rms(between circuit and housing)
|
Electromagnetic properties
|
IEC61326(EMC)
|
Suitable for safety regulations
|
IEC61010-1(CAT 300V,CAT IV 150V,pollution level
2); IEC61010-031; IEC61557-1(grounding resistance); IEC61557-5(soil resistivity); JJG 366-2004. |
Suppliers with verified business licenses