- Frequency range 9kHz - 1.5GHz
- -160 dBm Displayed Average Noise Level (DANL)
- Phase noise -80 dBc/Hz @1GHz and offset at 10 kHz
- Total amplitude accuracy <0.7 dB
- 1 Hz minimum resolution bandwidth (RBW)
- EMI pre-compliance test function (free), EMC test software (options)
- Optional Tracking Generator (can be upgraded to have TG after purchasing)
- Waterfall plot graphic, modulation signal quality analysis,
audio demodulation, ect. multiple general and extended
test functions.
- Standard Pass/Fail on-site test and alert function
- Adopt all-digital intermediate frequency technology
- Multiple interfaces: USB Host, USB Device, LAN,
earphone interface, HDMI
- 9-inch LCD, high resolution 1280×800 pixels
Frequency | ||||||
Frequency Range | XSA805 | 9 kHz to 500 MHz | ||||
XSA810 | 9 kHz to 1 GHz | |||||
XSA815 | 9 kHz to 1.5 GHz | |||||
Frequency Resolution | 1 Hz | |||||
Reference frequency aging rate | < 1 ppm/year | |||||
Frequency Span | ||||||
Span Range | 0 Hz, 100 Hz to max frequency of instrument | |||||
Span Uncertainty | ± span / (sweep points-1) | |||||
SSB Phase Noise(20ºC to 30ºC, fc = 500 MHz) | ||||||
Carrier Offset | 10 kHz | < -80 dBc/Hz | ||||
100 kHz | < -100 dBc/Hz | |||||
1 MHz | < -115 dBc/Hz | |||||
Bandwidth | ||||||
Resolution Bandwidth(-3 dB) | 1 Hz to 1 MHz, in 1-3-5-10 sequence | |||||
Resolution Bandwidth (-6 dB) (EMI) | 200 Hz, 9 kHz, 120 kHz, 1 MHz | |||||
RBW Accuracy | < 5% typical | |||||
Resolution Filter Shape Factor (60 dB : 3 dB) | < 5 typical | |||||
Video Bandwidth (-3 dB) |
10 Hz to 1 MHz, in 1-3-5-10 sequence | |||||
Amplitude and level | ||||||
Amplitude measurement range | DANL to +10 dBm, 100 kHz to 10 MHz, Preamp Off DANL to +20 dBm, fc ≥ 10 MHz, Preamp Off |
|||||
Reference Level | -80 dBm to +30 dBm, 0.01 dB by step | |||||
Preamp | 20 dB, nominal, 100 kHz to 1.5 GHz | |||||
Input Attenuator | 0 to 40 dB, 1 dB by step | |||||
Display Average Noise Level (Input attenuation = 0 dB, RBW = VBW = 100 Hz, sample detector, trace average ≥ 50, 20ºC to 30ºC, input impedance = 50 Ω) | ||||||
Preamp Off | 9 kHz to 1 MHz | -95 dBm (Typical), <-88 dBm | ||||
1 MHz to 500 MHz | -140 dBm (Typical), <-130dBm | |||||
XSA810 | 500 MHz to 1 GHz | |||||
XSA815 | 500 MHz to 1.5 GHz | -138 dBm (Typical), <-128 dBm | ||||
Preamp On | 100 kHz to 1 MHz | -135 dBm (Typical), <-128 dBm | ||||
1 MHz to 500 MHz | -160 dBm (Typical), <-150 dBm | |||||
XSA810 | 500 MHz to 1 GHz | |||||
XSA815 | 500 MHz to 1.5 GHz | -158 dBm (Typical), <-148 dBm | ||||
Level Display | ||||||
Trace detectors | positive-peak, negative-peak, normal, sample, RMS, voltage average, quasi-peak | |||||
Trace functions | clear write, max hold, min hold, average, view, blank, trace math | |||||
Units of level axis | dBm, dBμW, dBpW, dBmV, dBμV, W, V | |||||
Frequency response (fc ≥ 100 kHz, 20ºC to 30ºC,30% to 70% relative humidity, input attenuation=10 dB, reference frequency= 50 MHz) |
||||||
Preamp Off | <0.7 dB | |||||
Preamp On | <1.0 dB | |||||
Difference and Accuracy | ||||||
Uncertainty | fc = 50 MHz, peak detector, preamplifier off, attenuation = 10 dB, input signal level = -10 dBm, 20ºC to 30ºC | |||||
< 0.4 dB | ||||||
Level Measurement Uncertainty | ||||||
Level measurement uncertainty | 95% confidence level, S/N > 20 dB, RBW = VBW = 1 kHz, preamplifier off, attenuation = 10 dB, -50 dBm < input level ≤ 0 dBm, fc > 10 MHz, 20ºC to 30ºC | |||||
< 0.7 dB | ||||||
Tracking Generator (optional) | ||||||
Frequency Range | XSA805 | 100 kHz to 500 MHz | ||||
XSA810 | 100 kHz to 1 GHz | |||||
XSA815 | 100 kHz to 1.5 GHz | |||||
Output power level range |
-40 dBm to 0 dBm | |||||
Output level resolution | 1 dB | |||||
Output flatness | Relative to 50 MHz | |||||
± 3 dB | ||||||
Tracking generator spurious | Harmonic spurious | -30 dBc (Tracking generator output power -10 dBm) | ||||
Non-harmonic spurious | -40 dBc (Tracking generator output power -10 dBm) | |||||
Tracking generator to input terminal isolation | -60 dB (Tracking generator output power 0 dBm) | |||||
Interface | ||||||
USB Host, USB Device, LAN, earphone interface, HDMI | ||||||
Display | ||||||
9-inch TFT LCD, 1280 x 800 pixels | ||||||
Appearance | ||||||
Dimensions | 375 mm (W) × 185 mm (H) × 120 mm (D) | |||||
Weight | Approx. 3.7 kg (main device) |